MONICA EU Project

Logo

This work is supported by the European Commission through the MONICA H2020 PROJECT under grant agreement No 732350.

Tutorials

COP UI Tutorial for sound monitoring

This is a tutorial for how to use the COP (Common Operational Picture) UI and is based on using the Demonstration of Sound Monitoring an event using Sound Level Meters simulated demonstration.

Prerequistes

Demonstration of Sound Monitoring an event using Sound Level Meters needs to be launched in docker, follow the instructions there.

Introduction

The COP UI is a simple map based interface for displaying the current state of an event. The COP UI is built using predefined Points Of Interest POI, called instance data, and mixing it with sensor and service derived dynamic information. All the functionality exposed in the COP UI is using the COP API.

Basic Components of the UI

The user interface is built with a main menu that selects which view the user shown.

COP UI

In this case we have five modes:

The number views depends on the application and can include views for sound and incident management.

The SOUND view functionality

The SOUND view shows the “real time” data from the Sound Level Meters at the event. For each of the Sound Level Meters the following are shown:

The MAP view functionality

Zoom and movement of the MAP

In the MAP view the user can zoom in and out of the map and also move the MAP. All this is achieved by using the normal Google Maps interface, i.e dragging the map with the mouse or fingers, zoom by pinching or by using the “+” and “-“ controls in the map.

Sound heatmap

The map view for sound shows the calculated sound heat map. The Sound Heat Map Generator genarates the sound heat map using the sound level meters. Sound Heat Map As one can see there are three active stages at this event.

If the heat map is not shown, check the filter setting so that is selected for display: COP UI Filter

In the map the positions of the SLMs are also indicated. By clicking on the symbol a detail view will be shown with the name and id. There are additional SLMs placed in the neighbouring areas, by zooming out the map these can be seen. Detail

The AUDIENCE AREA functionality

The AUDIENCE AREA displays information about sound pressure levels in the audiencie area: Audience The sound pressure values for dBA and dBC are processed by the Decision Support System (DSS) producing a sliding average over time. Any exceedings of limits will generate incidents from the DSS which are shown in the Exceedings “box”.

The NEIGHBOUR AREA functionality

The NEIGHBOUR AREA displays information about sound pressure levels in the neighbourging areas. Neighbour It shows the sound pressure level and a 15 minute average. In addition to this it also display the calculated contribution of sound from the different stages. The calculations are done by the (DSS). In this case the limits have been exceeded a number of times and they are shown in the exceedings box.

In addition to the dBA there is also as a view of the calculated octave bands.

Neighbour

This also shows the calculated sound contribution from each of stages. You change the selected band by using the drop down list.